The optional ASCO
5500 Thin Web Server
provides Web-enabled
control.
An operator or
supervisor can monitor
various transfer switch,
engine and generator
parameters remotely using
the Thin Web Server.
The server provides
real time access and control
of critical power system
performance.
Users can manage,
check system status and
recognize potential system
failure.
It requires no dedicated
hardware or software
to operate and can be
connected to any standard
PC with a Microsoft
®
Internet Explorer browser.
E-mail and text paging
features alert users of
abnormal conditions.
Communication Products
The optional ASCO 5150
Connectivity Module pro-
vides Ethernet and RS485
Communications to ASCO
Transfer Switch controllers
and ASCO Power Managers.
Embedded HTML pages
are provided for monitoring
of electrical parameters and
alarms. The communication
ASCO 5150 Connectivity Module.
ASCO 5500 Thin Web Server.
Generator Breakers
9
Generator circuit
breakers offer drawout
convenience to simplify
maintenance or
replacement.
Electrically-operated
front-serviceable drawout
breakers are available in
800 amp to 3000 amp
frame sizes.The Square D,
NW, 5.0P insulated case
circuit breakers are UL 489
listed and are included with
an adjustable long time
delay, short time delay,
instantaneous overcurrent
trip and ground fault alarm.
Additional features
include 120VAC electrical
operation, 24 VDC shunt
trip, bell alarm, 4a and
4b auxiliary contacts, a
protective cover for the
manual close pushbutton,
and instantaneous and
ground fault indications.
Square D Micrologic
5.0P Trip units provide
monitoring of electrical
parameters as well as visual
indication. Trip settings
are adjustable from 40 %
to 100% of the generator
breaker frame size and
a Modbus
®
RTU port
provides communications
to the Emergency Power
Communication System.
Generator breaker and bus ampacity
1,3
1. Square D MASTERPACT
®
NW Insulated Case Circuit Breaker
2. Adjustable Trip Settings 40% to 100% of Breaker Frame Size
3. Bus bracing level 100,000 amperes.
2500
2500
2500
4000
4000
6000
6000
1000
1000
1000
1000
1000
2000
2000
GEN SIZE
(kw @480V)
Breaker Frame
(Amps)
Breaker Trip
(Amps)
2
Phase &Neutral
Bus (Amps)
Ground Bus
(Amps)
230 - 500
300 - 650
350 - 800
450 -1000
550 -1250
700 -1500
800 -2000
800
1200
1200
1600
2000
2500
3000
800
1000
1200
1600
2000
2500
3000
Sy S t e m F u n c t i o n S
Generator Protection
Device 27/59- Under
and Over Voltage
Device 81- Under and
Over Frequency
Device 32- Reverse
Power (Inverse Time
Delay)
Device 40- Loss of
Excitation
Device 81U- Bus Under
Frequency
Over Current (Inverse
Time Delay)
Synchronizing
Phase Match
Synchronization
3 Mode Operation: Run,
Check, Permissive
Voltage Matching
Dead Bus Closing
Synch Timer
Reclose Attempt/Timer
Manual Synchronization
(Permissive Mode)
Generator Voltage
And Reactive Load
Control
Power Factor Sharing In
Load Sharing Mode
Externally Adjustable
Var/Pf Reference
Manual Voltage Control
AC Metering
3 Phase Voltage
3 Phase Current
kWh
kW, kVA, and kVAR
Power Factor
Frequency
Engine Control
Multiple Crank Cycle
Timer
Crank Timer
Crank Fail Alarm/
Shutdown
Crank Cutout (Rpm)
Engine Preglow
Idle/Rated Relay Output
Engine Runtime
Engine Protection
Oil Pressure -Over/
Under Alarm/Shutdown
Settings
Water Temperature -
Over/Under Alarm/
Shutdown Settings
Battery Voltage - Over/
Under Alarm/Shutdown
Settings
Overspeed - Alarm/
Shutdown Settings
format will support up to 8
clients simultaniously over
an Ethernet Connection.
An ASCO 5110 communi-
cation module also available
with only RS485 communi-
cations for monitoring and
control with ASCO Power-
Quest
®
systems.
4
The ASCO 5350 Power
Transfer Switch Remote
Annunciator is a stand-
alone, industrial grade
interface device providing
you with the most critical
transfer switch status
indication and transfer/
retransfer control for up to
eight switches. Ethernet
technology is built in for
faster and more reliable
communications. LEDs
indicate switch status
and position, while
separate push buttons
individually initiate transfer
switch operation and
testing. Transfer switch
annunciators can be set
up in multiple locations to
monitor various transfer
switches, allowing
redundant and distributed
annunciation.