SB-E-DA-100-A DA-100 LVMP AUTOMATIC SPRAY GUN OPERATION MANUAL IMPORTANT: Read and follow all instructions and SAFETY PRECAUTIONS before using
SAFTEY PRECAUSTIONS This manual contains important information that ALL users should know and understand BEFORE using this equipment. This informa
HAZARD CAUSE SAFEGUARDS General Safety Improper operation or maintenance may create a hazard. Operators should be given adequate training in the sa
SPECIFICATION Max. Air Pressure: 0.69MPa (6.9 bar) Max. Fluid Pressure: 0.69MPa (6.9 bar) Cylinder Air Pressure: Min. 0.35MPa (3.5 bar) Max. 0
− 5 − CLEANING 1. Relieve air pressure from pressure tank. Carefully follow instructions in bulletin sent with tank. 2. Replace material in contain
Figure 5. Gun Exploded View Parts Sheet Ref No. Part Number Description Qty Remarks 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
SERVICE CHECK Normal Spray Pattern The proper combination of fluid pressure, fan and atomization air pressure, and fluid tip size should result i