Instruction Manual
D100391X012
EDR and ETR Valves
April 2011
3
Figure 2. Actuator Mounting
CAP SCREWS
INDICATOR SCALE
STEM LOCKNUTS
YOKE LOCKNUT
STEM CONNECTOR
INDICATOR DISK
ACTUATOR YOKE
PACKING FLANGE NUTS
BONNET
W2080‐1
Installation
WARNING
Always wear protective gloves, clothing, and eyewear when performing any installation operations.
To avoid personal injury or property damage resulting from the sudden release of pressure, do not install the valve
assembly where service conditions could exceed the limits given on the valve and actuator nameplates. Use
pressure‐relieving devices as required by accepted industry, local, state, or Federal codes, and good engineering practices.
Check with your process or safety engineer for any other hazards that may be present from exposure to process media.
If installing into an existing application, also refer to the WARNING at the beginning of the Maintenance section in this
instruction manual.
CAUTION
The valve configuration and construction materials were selected to meet particular pressure, temperature, pressure drop,
and controlled fluid conditions. Because some body/trim material combinations are limited in their pressure drop and
temperature range capabilities, do not exceed these conditions without first contacting your Emerson Process
Management sales office.
Inspect the valve and pipelines to ensure they are not damaged, are clean, and free of foreign material.