Instruction Manual
D100392X012
EH Valves NPS 8 through 14
July 2014
3
Educational Services
For information on available courses for the Fisher EH NPS 8 through14valve,aswellasavariety of other products,
contact:
Emerson Process Management
Educational Services - Registration
Phone: 1-641-754-3771 or 1-800-338-8158
http://www.emersonprocess.com/education
Table 3. Additional Shutoff Classification
Valve Design
(PRESSURE RATING)
Valve Size, NPS Port Diameter, Inches Cage Style
ANSI/FCI Leakage
Class
EHD
(CL1500)
8
10
7
Equal Percentage
Modified Equal Percentage
Linear (std. cage)
Linear (Whisper III, A1, B3, C3)
Vwith
optional Bore seal trim
EHD
(CL2500)
8
10
5.375
Equal Percentage, Modified Equal Percentage,
Linear (std. cage),
Linear (Whisper III, A1, B3, C3, D3)
Vwith
optional Bore seal trim)
12
14
7
Equal Percentage, Modified Equal Percentage,
Linear (std. cage),
Linear (Whisper III, A1, B3, C3, D3)
Vwith
optional Bore seal trim)
Table 4. Approximate Weights (Valve Body and Bonnet Assemblies)
VALVE
SIZE,
NPS
WEIGHTS
CL1500 CL2500
Buttwelding Ends Flanged Buttwelding Ends Flanged
Kilograms Pounds Kilograms Pounds Kilograms Pounds Kilograms Pounds
8 1400 3100 1700 3700 1900 4100 2200 4700
10 1500 3300 1900 4100 2000 4400 --- ---
12 3400 7300 3900 8600 3400 7600 --- ---
14 3400 7300 --- --- 3400 7600 --- ---
Installation
WARNING
Always wear protective gloves, clothing, and eyewear when performing any installation operations to avoid personal
injury.
To avoid personal injury or property damage resulting from the sudden release of pressure, do not install the valve
assembly where service conditions could exceed the limits given in this manual or on the appropriate nameplates. Use
pressure-relieving devices as required by government or accepted industry codes and good engineering practices.
Check with your process or safety engineer for any additional measures that must be taken to protect against process
media.
If installing into an existing application, also refer to the WARNING at the beginning of the Maintenance section in this
instruction manual.