Density performance (liquid only)
Pressure ratings
kg/m
3
Accuracy
(1)
(1) Accuracy includes the combined effects of repeatability, linearity, and hysteresis. Accuracy specifications are based on reference
conditions of water at 20 to 25 °C and 1 to 2 bar, unless otherwise noted.
±0,5
Repeatability ±0,2
Range up to 5000
Sensor rating
(1)
(1) Process connection rating may differ from sensor rating. Please choose process connections accordingly.
316L and 304L stainless
steel
Hastelloy C-22
bar bar
CMF025 103 190
CMF050 103 185
CMF100 100 170
CMF200 108 190
PED compliance Sensors comply with council directive 97/23/EC of 29 May 1997 on Pressure Equipment
Dual seal compliance CSA sensors comply with ANSI/ISA 12.27.01-2003 requirements for process sealing between
electrical systems and flammable or combustible process fluids
ASME B31.3 secondary
containment rating
(2)
(2) For operating temperatures above 148 °C, pressure needs to be derated as follows. Linear interpolation may be used between
values. Process connection derating may differ from sensor rating.
Burst pressure
Housing rating bar bar
CMF025 58 377
CMF050 58 364
CMF100 43 227
CMF200 37 192
Flow tubes Housing
316L sensors 304L sensors Hastelloy C-22
sensors
All sensors
up to 148 °C None None None None
at 204 °C 7,2% derating 5,4% derating None 5,4% derating