D103411X012 April 2012
Field Communicator Menu Tree - DVC6200 Digital Valve Controller
www.Fisher.com
FIELDVUE™ DVC6200 Digital Valve Controller
Menu Tree applies to:
Fisher and FIELDVUE are marks owned by one of the companies in the Emerson Process
Management business unit of Emerson Electric Co. Emerson, Emerson Process Management,
and the Emerson logo are trademarks and service marks of Emerson Electric Co. HART is a
mark owned by the HART Communication Foundation. All other marks are the property of
their respective owners.
Instrument Level HC, AD, PD, and ODV
Device Revision DD RevisionFirmware Revision
2 7, 9, & 10 7
Hot Key
1 Instrument Mode
2 Control Mode
3 Protection
4 Stabilize/Optimize
Online
1 Configure
2 Service Tools
3 Overview
Calibrate
1 Travel Calibration
2 Sensor Calibration
3 Relay
4 Restore Factory
5 PST Calibration
Configure
1 Guided Setup
2 Detailed Setup
3 Calibrate
HART Applications
1 Offline
2 Online
3 Utility
4 HART Diagnostics
1
Service Tools
1 Alert Conditions
2 Status
3 Device Record
4 Stroke Valve
5 Partial Stroke Test
Overview
1 Analog In
2 Setpoint
3 Travel
4 Drive Signal
5 Pressure
6 Variables
7 Device Information
8 DD Information
1
1‐3
3
2
3‐5
3
Guided Setup
1 Setup Wizard
2 Performance Tuner
2 Stabilize/Optimize
1‐1
Detailed Setup
1 Mode/Protection
2 Response Control
3 Alert Setup
4 Status
5 Instrument
6 Valve and Actuator
7 SIS/Partial Stroke
1‐2
3
SIS/Partial Stroke
1 PST Enable
2 PST Enable
3 View/Edit PST Variables
1‐2‐7
4
1
2
3
4
5
Notes:
1‐1‐1 indicates fast‐key sequence to reach menu
This menu is available by pressing the left
arrow key from the previous menu
Instrument level AD, PD, and ODV only
Instrument level ODV only
Instrument level HC, AD, and PD only
Instrument level HC only
Device Information
1 HART Tag
2 Device ID
3 Manufacturer
4 Model
5 Device Revision
6 Firmware Revision
7 Hardware Revision
8 Instrument Level
9 HART Universal Revision
Pressure
1 Pressure A
2 Pressure B
3 A minus B
4 Supply
3‐7
Variables
1 Auxiliary Input
2 Temperature
3 Maximum Recorded Temperature
4 Minimum Recorded Temperature
5 Cycle Counter
6 Travel Accumulator
7 Raw Travel Input
8 View Number of Days Powered Up
9 Number of Power Ups
3‐6
2
2‐3
Valve & Actuator
1 Manufacturer
2 Valve Serial Number
3 Valve Style
4 Actuator Style
5 Travel Sensor Motion
6 View/Edit Feedback
   Connection
7 Assembly Specification Sheet
1‐2‐6
2
1‐2‐1
Mode/Protection
1 Instrument Mode
2 Control Mode
3 Restart Control Mode
4 Burst Mode
5 Protection
1‐2‐2
Travel Calibration
1 Auto Calibration
2 Manual Calibration
1‐3‐1
1‐3‐2
Sensor Calibration
1 Pressure Sensors
2 Travel Sensor
3 Analog In
Alert Setup
1 Electronics Alerts
2 Sensor Alerts
3 Environment Alerts
4 Travel Alerts
5 Travel History Alerts
6 SIS Alerts
6 Alert Record
Response Control
1 Tuning
2 Travel/Pressure Control
3 Input Characterization
4 Custom Characterization Table
5 Dynamic Response
Burst Mode
1 Burst Enable
2 Change Burst Enable
3 Burst Command
4 Change Burst Command
5 Cmd 3 Configured Pressure
Tuning
1 Travel Tuning
2 Integral Settings
3 Pressure Tuning
Travel/Pressure Control
1 Travel/Pressure Select
2 Cutoffs and Limits
3 Pressure Control
4 End Point Pressure Control
Dynamic Response
1 SP Rate Open
2 SP Rate Close
3 View/Edit Lag Time
3 View/Edit Lead/Lag
1‐2‐4
1‐2‐1‐4
1‐2‐2‐1
1‐2‐2‐2
1‐2‐5‐9
Units
1 Pressure Units
2 Temperature Units
3 Analog In Units
Analog Input Range
1 Input Range Hi
2 Input Range Lo
Calib Status and Type
1 Last AutoCal Status
2 Last Calibration Type
General
1 HART Tag
2 Message
3 Descriptor
4 Date
5 Valve Serial Number
6 Instrument Serial Number
7 Polling Address
Instrument
1 General
2 Units
3 Analog Input Range
4 Relay Type
5 Zero Power Condition
6 Maximum Supply Pressure
7 Auxiliary Terminal Action
8 Instrument Date and Time
9 Calib Status and Type
1‐2‐5
1‐2‐5‐1
1‐2‐5‐2
1‐2‐5‐3
Status
1 Instrument Time
2 Calibration and Diagnostics
3 Operational
4 Integrator Saturation
1‐2‐2‐5
Travel Tuning
1 Travel Tuning Set
2 Integral Enable
3 Integral Gain
4 Stabilize/Optimize
4 Performance Tuner
Integral Settings
1 Integral Dead Zone
2 Integral Limit
Pressure Tuning
1 Pressure Tuning Set
2 Integral Enable
3 Integral Gain
Cutoffs and Limits
1 Cutoff Hi
2 Cutoff Lo
3 Change Cutoffs
4 Travel Limit Hi
5 Travel Limit Lo
6 Change Travel Limits
Pressure Control
1 Pressure Range Hi
2 Pressure Range Lo
1‐2‐2‐1‐1
1‐2‐2‐2‐2
End Point Pressure Control
1 End Pt Control Enab
2 PST Start Point
3 EPPC Setup Point
4 EPPS Saturation Time
1‐2‐2‐1‐2
1‐2‐2‐1‐3
1‐2‐2‐2‐3
1‐2‐2‐2‐4
Integrator Saturation
1 Integrator Sat Hi Enable
2 Integrator Sat Lo Enable
3 Integral Limit
4 Integral Dead Zone
Instrument Time
1 Inst Time Invalid Enable
2 Instrument Date and Time
1‐2‐4‐1
1‐2‐4‐4
Operational
1 Pressure Control Active Enable
2 Multi‐Drop Enable
Calibration and Diagnostics
1 Calibration in Progress Enable
2 Autocal in Progress Enable
3 Diagnostic in Progress Enable
4 Diagnostic Data Avail Enable
Electronics Alerts
1 Drive Current Shutdown
2 Drive Signal Alert
3 Processor Impaired Alerts
Drive Signal Alert
1 Drive Signal Alert Enable
2 Drive Signal
Processor Impaired Alerts
1 Offline/Failed Alert Enable
2 Low Power Write Fail Enable
3 Non‐Critical NVM Alert Enable
4 Critical NVM Shutdown
5 Flash ROM Shutdown
6 No Free Time Shutdown
7 Reference Voltage Shutdown
REVERSE
1‐2‐4‐3
1‐2‐4‐2
1‐2‐3‐1
1‐2‐3‐1‐2
1‐2‐3‐1‐3
5
SIDE
2
6
Fast key sequence for Alert Record with
instrument level ODV is 1‐2‐3‐7
6
3
E 2010, 2012 Fisher Controls International LLC. All rights reserved.
3
475 Field
Communicator
ON
1‐2‐3
Hardware Revision
1
3
3
2
Device Record
1 Maximum Recorded Temperature
2 Minimum Recorded Temperature
3 View Number of Days Powered Up
4 Number of Power Ups
3
4
3
www.FIELDVUE.com
For the telephone number of the Emerson Process
Management sales office nearest you, contact:
In North America
Fisher Controls International LLC
1 (641) 754‐3011
In Latin America
Fisher Controls International LLC
1 (314) 746‐9900
In Asia Pacific
Emerson Process Management
Asia Pacific Private Ltd.
(65) 6777‐8211
In Europe
Emerson Process Management Ltd.
+44 1634 895800
For equipment service or support needs, contact
your local Emerson Process Management sales office.
Page view 0
1 2

Summary of Contents

Page 1 - Menu Tree applies to:

D103411X012 April 2012Field Communicator Menu Tree - DVC6200 Digital Valve Controllerwww.Fisher.comFIELDVUE™ DVC6200 Digital Valve ControllerMenu

Page 2

Function/Variable Fast‐Key SequenceActuator Style 1‐2‐6‐4Alert Conditions 2‐1Alert Record1‐2‐3‐61‐2‐3‐7Analog Input 3‐1Analog Input Range 1‐2‐5‐3Analo