25 2006SSD-75 R4 (10/10) 24 2006SSD-75 R4 (10/10)
Dual-Compressor Module Troubleshooting
24 2006SSD-75 R4 (10/10)
5.0 troubleshootiNg
This section offers tips for troubleshooting.
5.1 Troubleshooting Guide
Refer to Table 4 for recommended solutions to typical problems.
Table 4 Troubleshooting
Problem Recommended Actions
Low Inlet
Gas Pressure
Fault
Closed gas inlet valve.
Restricted or insufcient gas supply.
Blocked inlet lter/screen (located internally on the Compressor Module inlet block).
High Oil
Temperature
Fault
Blocked air ow across oil cooler.
Ensure cooling fans are operating when the unit is running and up to temperature; at
approximately 180°F (82°C), fans should start to run at minimum speed.
Ensure adequate oil level in rst-stage separator (see 4.3 - Checking the Oil Level on
page 19).
High Discharge
Pressure Fault
Restricted discharge and bypass valve fault.
VFD Fault The drive LED will display the specic fault
5.2 Motor Winding Resistance
Table 5 Motor winding resistance
Compressor
Model Motor Winding Resistance
C1A and C3A
Phase-to-phase
= 1.2 to 1.4 ohms
C2A
Phase-to-phase
= 0.7 ohms
All Compressor
Modules
Phase-to-ground
= Innity