Model 3200 HP
High Purity Water pH Sensor
with pHaser
TM
Flowing Junction
Instruction Manual
51A-3200HP/rev.C
June 2008
SPECIFICATIONS
Sensor Type:
3200HP
Part Number:
3200HP-01, -02, -03, HPO and 3200HP-OEM, -OEM-01, -OEM-02, -OEM-03
Accuracy:
±
0.05 pH
Noise: < 0.02pH
Drift: < 0.05 pH per week
Conductivity Range: > 0.4 µS/cm
Sample flow rate: 1 - 3 gph (60 - 180 mL/min)
Wetted Materials: Silicone, polycarbonate/polyester, glass, stainless steel, PVDF, Viton
1
Sample Temperature: 0
o
C - 70
o
C (32
o
F to 160
o
F)
Sample pressure: 5 - 10 psig – drain to atmosphere.
Process connection: 1/4 inch FNPT
Reference Electrode: Flowing open capillary
Weight/Shipping Weight: 5.4lb/7.6lb (2.5kg/3.5kg)
VP6 Cable Connection: 10ft use PN 23645-10
20ft use PN 23645-11
30ft use PN 23645-12
For additional information, please refer to the Instruction Manuals CD shipped with this
product, or visit our website at www.emersonprocess.com/raihome/liquid/.
1. Viton is a registered trademark of DuPont Performance Elastomers.
The wetted sensor materials may not be compatible
with process com position and operating conditions.
Application compat ibility is entirely the
responsi-
bility of the user.
NOTICE
SENSOR/PROCESS
APPLICATION COMPATIBILITY
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - High Purity Water pH Sensor

Model 3200 HPHigh Purity Water pH Sensorwith pHaserTMFlowing JunctionInstruction Manual51A-3200HP/rev.CJune 2008SPECIFICATIONSSensor Type: 3200HPPart

Page 2 - REPLACEMENT PARTS

10FIGURE 11. Model 1055-01-10-22-32 WiringFIGURE 12. Wiring Details with Remote J-Box and Preamp (PN 23555-00)MODEL 3200 HP Wiring54e5081-P

Page 3 - MODEL 3200 HP Installation

11MODEL 3200 HP WiringFIGURE 15. Model 1056-01-22-38-ANFIGURE 13. Model 1055-01-10-SIFIGURE 14. Model 1055-01-11-SI

Page 4 - REPLACING THE CAPILLARY DISC

Credit Cards for U.S. Purchases Only.The right people,the right answers,right now.ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITEhttp://www.raihome.com

Page 5

2MODEL 3200HP InstallationINSTALLATION1. Refer to Figure 1.2. Mount the back plate on a wall or Sample Panel3. Remove the bag containing the Dif

Page 6 - TROUBLESHOOTING

3PUTTING THE 3200 HP IN SERVICE1. Wire the Varipol (VP) cable to the analyzer. See the wiring diagrams in the WIRING section.2. Start the sample flow.

Page 7 - PN 23645-10,11 & 12

4MODEL 3200 HP CalibrationCALIBRATION1. Select two stable buffer solutions, preferably pH 7.0 and 10.0. Ideally, the calibration buffers should bracke

Page 8 - FIGURE 8. Model 54e Wiring

5MODEL 3200 HP Replacement Parts REPLACING THE CAPILLARY DISC CONT.8. Remove the shipping plug from the reservoir filter. Attach the tube to the reser

Page 9

6MODEL 3200 HP TroubleshootingTROUBLESHOOTINGProblem Cause SolutionpH reading in errorNoisy pH read

Page 10 - MODEL 3200 HP Wiring

FIGURE 5. Model Xmt-P-10 Panel Mount EnclosureFIGURE 6. Model Xmt-P-11 Pipe/Surface Mount Enclosure WiringFIGURE 4. Wire Functions for Variopol connec

Page 11

8MODEL 3200 HP WiringFIGURE 7. Model 5081-P WiringFIGURE 8. Model 54e Wiring

Page 12 - The right people

9MODEL 3200 HP WiringFIGURE 9. Model 1055-10-22 Panel Mount Enclosure WiringFIGURE 10. Model 1055-11-22 Pipe/Surface Mount Enclosure Wiring

Comments to this Manuals

No comments