Emerson LK90 Owner's Manual

Browse online or download Owner's Manual for Electric food choppers Emerson LK90. Emerson LK90 Owner's Manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
and 5). The neutral and line (hot) wires
in step 5)to make connections(Figures 4
light fixture(Figure 4). Connect the blue
1. Install three 60-watt (maximum) candelabra
base bulbs into the fitter sockets.
2. Depending on the model purchased, insert
the fan speed control switch chain through
the offset hole in the glass bowl or the hole
in the bowl cap.
3. Install the light switch chain through the
center of the finial nut. Screw the finial nut
finger tight onto the fitters threaded nipple.
CAUTION
Be sure that the fan switch chain does not
make contact with the light bulbs. If
necessary reposition the light fitter to avoid
the fan switch chain from touching the light
bulbs.
4. Install pendants onto light fixture chain and
fan switch chain.
NOTE: It is advisable to periodically check
the tightness of the finial.
5. Installation is complete. Turn on electricity at
main fuse or circuit breaker box.
Form No.
BP7438
Part No. F40BP74380000
Part No. F40BP74380000 Form No. BP7438
ETL Model No.: LK90, LK91, LK140, LK141
Printed in China 06/11
6.
7. Carefully tuck all wires and splices into
the switch housing(1).
8. Attach the cover/light fitter(5)(6) to the
switch assembly housing(1) using the
two screws(2) that were removed in
Step 2) (Figure 4.)
9. Proceed to “Installation of Glass Bowl”
section.
Installation of Glass Bowl
To avoid fire hazard, do not exceed
wattage indicated on the fixture.
THREADED NIPPLE
(1) GLASS
BOWL
OUTER BOWL CAP
(not on all light kits)
(3) FINIAL
LIGHT SWITCH
CHAIN
PENDANTS (2)
BOWL CAP
LIGHT FITTER
FAN SWITCH
CHAIN
WARNING
!
To avoid fire or electrical shock, be
careful not to pinch wires between
the switch housing assembly and
the cover.
WARNING
!
Over lamping the light kit will result in
the lamps being automatically shut off.
Use only 60-watt maximum candelabra
lamps. Turn off electricity before
replacing the lamps.
WARNING
!
Figure 5
To avoid possible fire or electrical
shock, make certain no bare wire
strands are exposed outside wire
connectors.
WARNING
!
NOTE: YOUR GLASS MAY
NOT LOOK THE SAME AS
THE ONE IN THIS
ILLUSTRATION. HOWEVER,
IT INSTALLS IN A SIMILAR
MANNER.
Ceiling Fan Light Fixture
Owner's Manual
LIMITED WARRANTY
What The Warranty Covers:
All products covered by this Owner’s Manual are warranted against all defects in workmanship and materials. You must be the original purchaser or user of the
product to be covered.
What The Period Of Coverage Is:
All components are covered by this warranty for one year from the date you purchased your light fixture. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Electric Co. Do To Correct Problems:
Emerson Electric Co. will replace a defective Emerson Light Fixture at no charge to you. WE WILL SHIP THE REPAIRED PRODUCT OR REPLACEMENT TO YOU AT
NO CHARGE, BUT YOU ARE RESPONSIBLE FOR ALL COSTS OF REMOVAL, REINSTALLATION AND SHIPPING OF THE PRODUCT TO EMERSON.
How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE LIGHT FIXTURE TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF
OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of Emerson
Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.
To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Light Fixture should
be properly packed to avoid damage in transit since we will not be responsible for any such damage.
What Is Not Covered:
This warranty also does not cover any defects, malfunctions or failures caused by:
Repairs by persons not authorized by Emerson Electric Co.,
Use of parts or accessories not authorized by Emerson Electric Co.,
Mishandling, improper installation, modifications or damage to your light fixture while in your possession, or
Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
The original purchaser or user ceases to own the product, or
The ceiling fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee,
agent, dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR
DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such damages as loss
of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product
does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
READ AND SAVE THESE INSTRUCTIONS
USE THESE FIXTURES ONLY WITH EMERSON
CF SERIES CEILING FANS.
Ceiling Fan Light Fixture
SUITABLE FOR DAMP LOCATIONS
THREE 60-WATT CANDELABRA BULBS
NOTE: ANY LIGHT KIT OR FITTER AND GLASS COMBINATION
COVERED BY THIS MANUAL WEIGHS 5.8 LBS. OR LESS.
Air Comfort Products
DIVISION OF EMERSON ELECTRIC CO.
8100 W. Florissant ¥ St. Louis, MO 63136
Figure 6
For repair parts, phone:
1-800-654-3545
NOTE: Some light kit models provide a hole
in the glass bowl for the fan switch chain.
proper polarity at the lampholders.
must be installed as instructed to maintain
listed wire connectors (previously removed
black line(hot)wire of the light fixture.Use
line(hot)wire from the switch cup to the
Connect the white neutral wire from the
Page view 0
1 2

Summary of Contents

Page 1 - Ceiling Fan Light Fixture

and 5). The neutral and line (hot) wiresin step 5)to make connections(Figures 4light fixture(Figure 4). Connect the blue1. Install three 60-watt (maxi

Page 2

and 3). The neutral and line (hot) wiresin step 5)to make connections(Figures 2light fixture(Figure 2). Connect the blueswi7.Insert the black and whit

Comments to this Manuals

No comments